What was found
DURING INSPECTION OF LH WING LOWR PLANK ACCES HOLE PITTING WAS FOUND (550BB) (C CHECK) RO 3/2/2020 ACCOMPLISHED REPAIR OF LH WING LOWER PLANK ACCESS PANEL LANDING 550BB IAW REO REV. BLEND FOUND INSIDE OF CRITICAL AREA. ORIGINAL .182, REMOVED .002, REMAINING .180 CONTIUNED MONITORING REQUIRED. BOND CHECK GOOD, LEAK CHECK GOOD. PIN POINT MIC AV8098 DEC 20, EDDY CURRENT AV 8958 JUL 20 ULTRASONIC AV8959 JUL 20, TACH AV 1335 JUL 20, REGULATOR AG1157 OCT 20, MILLIOHMETER AV 6346 AUG 20, TORQUE WRENCH AV7330 NOV 20