Service difficulty report · Door Sill · Cndair CL6002B19

Difficulty date
January 21, 2020
Submitted
March 10, 2020
Operation
Air carrier
Aircraft
N905EV
Make and model
Cndair CL6002B19
Aircraft serial
7632
Aircraft time
39,265 hours, 36,176 cycles
Part
Door Sill
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

* THE RH FLOOR SILL AT FS 319.00 HAS CORROSION. (MARKED) (C CHECK) RO 3/7/2020 REMOVED CORROSION TO THE R/H FLOOR SILL AT FS 319.00 PER REF: CRJ200 SRM. GALLEY SUPPORT ANGLE ORIGINAL THICKNESS IS .090", AMOUNT REMAINING IS .087" REF NDT, REMOVED .003" AND MAX ALLOWABLE IS .009" AND THEREFORE THE ANGLE/ DOUBLER IS IN LIMITS OF CRJ 200 SRM 53-00-00. ORIGINAL THICKNESS OF THE RH FLOOR SILL IS .063" AMOUNT REMAINING IS .027" REF NDT, REMOVED .036" AND MAX ALLOWABLE IS .0063" THEREFORE THE SILL IS OUT OF LIMITS REF CRJ 200 SRM. REMOVED AND REPLACED THE SILL IAW CRJ 200 SRM. PRESSURE LEAK CHECKS GOOD.