As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WINDSHIELD CENTER POST LOWER LH & RH ATTACH FITTINGS CRACKED IN RADIUS. MARKED IN RED. (C CHECK) RO 3/7/2020 REMOVED CRACKED ATTACH FITTINGS AND INSTALLED NEW ATTACH FITTINGS 2EA. IN THE WINDSHIELD CENTER POST REF BOMBARDIER DWG AND CRJ 200 SRM. SEE CONTINUATION CARD FOR DETAILS.