As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*CORROSION SUPPORT ANGLES CORRODED AT FASTENER LOCATIONS ON INBD SIDE OF FLOORBEAM FROM FS 409.00 - 406.00+96 ST LBL 9 (MARKED)REMOVED AND INSTALLED NEW FLOOR BEAM FROM 409.00 - 409 +96 AT LBL 9 REF, BOMBARDIER DWG. CRJ 200 SRM. COMPLIED WITH TASK CARD