What was found
THE FLOORBEAM AT LBL9.00 FROM FS409.00 TO FS409.00+128 HAS MULTIPLE LOCATIONS OF CORROSION. (MARKED) (C CHECK) RO 3/27/2020 REMOVED CORROSION FROM FLOOR BEAM AT LBL 9.00 FROM FS. 409.00 TO FS. 409.00+128 IAW REO ( SEE CONTINUATION CARD FOR DETAILS ).