Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
March 6, 2020
Submitted
May 1, 2020
Operation
Air carrier
Aircraft
N889AS
Make and model
Cndair CL6002B19
Aircraft serial
7538
Aircraft time
38,385 hours, 37,102 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FS409.00+5 LBL9 THRU FS409.00+119 LBL9 FLOOR SUPPORT UPPER CAP SURFACE FOUND TO BE OUT OF LIMITS FOLLOWING CORROSION REMOVAL. (C-CHECK) RO 4/30/2020 REMOVED AND REPLACED FLOOR SUPPORT FS409+5 - FS409+115 LBL9 DUE TO CORROSION OUT OF LIMITS IAW CRJ200 AMM SRM NDTM. ALSO BOMBARDIER DRAWING. COMPLIED WITH SKY CARD (CL600-2B19) STRUCTURAL REPAIR. WEIGHT AND BALANCE NOT AFFECTED, REPLACEMENT PART EQUAL WEIGHT TO ORIGINAL.