What was found
CORROSION AT NUTPLATES FROM FRAME 559+112 TO FRAME 621 AT FLOOR (7 EA). R/H SIDE (C-CHECK) RO 4/30/2020 REMOVED 7 EACH NUTPLATES BETWEEN FRAME 559+112 AND 621 AT FLOOR STRUCTURE R/H SIDE IAW CRJ200 SRM, REMOVED LIGHT SURFACE CORROSION BY HAND AROUND NUTPLATES IAW CRJ200 SRM, APPLIED ALODINE,PRIMER, AND TOPCOAT IAW CRJ200 SRM, CRJ200 SRM AND CRJ200 SRM, INSTALLED 7EACH NUTPLATES BETWEEN FRAME 559+112 AND FRAME 621 AT FLOOR STRUCTURE R/H SIDE IAW CRJ200 SRM