What was found
D: COMPLIED WITH TEMPORARY REPAIR, REINFORCING ANGLE, TO DAMAGED AREA AT FS654.00 STGR 8R REF. PER REO. UPON EXPIRATION OF THIS REO, FRAME 654.50 MUST BE REPLACED. PERMANENT REPAIR DUE IN 6000 FLT HRS BY TAT 40364.4. C: MCI RA# 39629 *** DO NOT CLOSE UNTIL PERMANENT REPAIR *** (C-CHECK) RO 5/16/2020 COMPLIED WITH PERMANENT REPAIR OF THE FS 654 STGR 8R FRAME BY REPLACING FRAME P/N 601-36002-29 IAW CRJ 200 SRM. NO WEIGHT CHANGE REQUIRED. M-337 ATTACHED