Service difficulty report · I/O Module · Emb ERJ170200LR

Difficulty date
June 9, 2020
Submitted
June 9, 2020
Operation
Air carrier
Aircraft
N113SY
Make and model
Emb ERJ170200LR
Aircraft serial
17000407
Aircraft time
17,359 hours, 9,344 cycles
Part
I/O Module
Condition
Failed
Stage of operation
LD
How discovered
O
Nature of condition
G, J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON LANDING LG WOW SYS FAIL CAUTION MESSAGE. AUTO BRAKES DID NOT WORK. THRUST REVERSE DID NOT WORK. GROUND LIFT DUMP DID NOT DEPLOY. MAX MANUAL BRAKING RESULTED IN USING ENTIRE RUNWAY TO STOP AIRCRAFT. MESSAGE CLEARED ON TAXI. FLIGHT 5276 - FILLED CLOSED INTERROGATED CMC, FOUND GENERIC I/O MODULE FAULTED (FAULT CODE 32600010UT, REMOVED AND REPLACED DENERIC I/O MODULE 1 IN REFERENCE TO AMM. PERFORMED THRUST REVERSER FUNCTIONAL CHECK IN REFERENCE TO AMM, MAIN-BRAKE AUTO BRAKE SYSTEM FUNCTIONAL CHECK IN REFERENCE TO AMM, AND SPOILER SYSTEM OPERATIONAL TEST IN REFERENCE TO AMM. ALL OPS CHECKS GOOD AT THIS TIME.