PAX DOOR FLOOR SUPPORT ANGLE CORRODED. (C-CHECK) RO 4/23/2020 BLENDED PAX DOOR FLOOR SUPPORT ANGLE REF SRM. BLENDED AREA FOUND TO BE OUT OF LIMITS REF SRM. REMOVED AND INSTALLED NEW PAX DOOR FLOOR SUPPORT ANGLE REF SRM. SEE CONTINUATION CARD FOR DETAILS.