As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD WET AREA-FLOOR CROSS BEAM FR 14; RBL 11" HAS SPOT OF CORROSION IN TOP FLANGE AT RH SEAT TRACK INTERSECTION POINT. CORROSION ON THE FWD WET AREA-FLOOR CROSS BEAM FR 14; RBL 11 FOUND TO BE OUT OF ALLOWABLE LIMITS REF SRM, PERFORMED CROSSBEAM REPAIR BY CUTTING OUT THE DAMAGE AND INSTALLING FILLER AND DOUBLER REF SRM.