Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
July 14, 2020
Submitted
September 2, 2020
Operation
Air carrier
Aircraft
N917EV
Make and model
Cndair CL6002B19
Aircraft serial
7769
Aircraft time
34,755 hours, 34,476 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 409-559
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT CABIN PRESSURE FLOOR SILL HAS CORROSION FROM FS409+128 TO FS 559.00 ON BOTH THE FLOOR SILL PANEL AND FLOOR ANGLES. C-CHECK RO 8/29/2020. REPAIRED RT CABIN FLOOR SILL IAW MHIRJ REO AND CRJ 200 SRM. COMPLIED WITH SKYCARD AND FORM M-337. SEE CONTINUATION CARD FOR DETAILS OF WORK PREFORMED. WEIGHT AND BALANCE NOT AFFECTED.