What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA53539-670-53-21-1660, MXCODEID49248-PR. CRACK LOCATED AT FS389 STR19 LT ON CENTER ROW OF LAP OF OUTER SKIN AREA, REPAIRED IAW SRM. THE REPAIR COMPLETED 10/18/2006 DOESN'T FOLLOW SRM REQUIREMENTS. THE SUBJECT CONDITION IS STRUCTURALLY ACCEPTABLE FOR 2000 FLIGHT HOURS FROM INCORPORATION OF REO AT THAT TIME, PERMANENT REPAIR MUST BE ACCOMPLISHED, IAW REO, PART NUMBER: - , SERIAL NUMBER: 10221, POSITION. C-CHECK RO 9/5/2020. COMPLIED WITH PERMANENT REPAIR LOCATED AT FS389 STR19 LT ON CENTER ROW OF LAP OF OUTER SKIN AREA, REF MHIRJ REO. PRESSURE CHECK GOOD. COMPLIED WITH TASKCARD.