As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT CENTER HORIZONTAL STAB ELEVATOR HINGE FITTING HAVE ABRASION DAMAGE, AS MARKED. C-CHECK RO 9/12/2020. BLENDED CHAFED AREA ON THE LT CENTER HORIZONTAL STAB ELEVATOR HINGE FITTING TO A SMOOTH CONTOUR. NDT CHECKED FOR CRACKS WITH NO DEFECTS NOTED. ROTO-PEENED BLENDED SURFACE AND RESTORED FINISH TO RE-WORKED AREA, REF MHI-RJ REO. COMPLIED WITH TASK CARD.