What was found
WHILE WORKING SERVICE DOOR SURROUND STRUCTURE LWR SILL FOUND SERVICE DOOR AFT LOWER SILL TO BE CORRODED. (C-CHECK RO 1/26/2025) REMOVED AND REPLACED SERVICE DOOR SURROUND STRUCTURE LWR SILL P/N 601R38303-253 IAW CRJ200 SRM 51-42-02. TASK CARD 51-900-1003-SKY COMPLETED. M-337 ATTACHED. CPCP CARD MANUALLY EMAILED.