What was found
CORROSION ON LT FLOOR SILL BETWEEN FS 517.00 FS 533.00, MARKED. C-CHECK RO 9/21/2020. REMOVED CORROSION ON LT FLOOR SILL BETWEEN FS 517.00 TO FS 533.00, REF CRJ700 SRM. EVALUATED BLENDS NR 1, NR 2 AND NR 3 ON LT FLOOR SILL BETWEEN FS 517.00 TO FS 533.00 ORIGINAL MATERIAL THICKNESS 0.050", REF CRJ700 SRM. MAXIMUM MATERIAL REMOVED 0.002", REMAINING MATERIAL THICKNESS 0.048". ALL BLENDS FOUND TO BE WITHIN LIMITS, REF CRJ700 SRM. RESTORED FINISH AT REWORKED AREAS LT FLOOR SILL BETWEEN FS 517-FS 533, REF CRJ700 SRM.