As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FWD WET AREA FR 17 CROSSBEAM AS MARKED IN BETWEEN LT AND RT FLOOR TRACKS. C-CHECK RO 9/24/2020. PERFORMED CUTOUT OF CORROSION ON FRAME 17 CROSSBEAM. FABRICATED AND INSTALLED FILLER AND DOUBLER, REF EMB SRM. ADDED WEIGHT DOES NOT CHANGE WEIGHT AND BALANCE. SEE CONTINUATION CARD FOR WORK PERFORMED.