What was found
CORROSION, FLOOR SPLICE AT FR 90 Y= -11". C-CHECK RO 10/12/2020. REMOVED AND REPLACED FLOOR SPLICE AT FR 90 Y= -11". PRE-TREATED BARE METAL AND APPLIED PRIMER, REF SRM PO 256693.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION, FLOOR SPLICE AT FR 90 Y= -11". C-CHECK RO 10/12/2020. REMOVED AND REPLACED FLOOR SPLICE AT FR 90 Y= -11". PRE-TREATED BARE METAL AND APPLIED PRIMER, REF SRM PO 256693.