Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
September 14, 2020
Submitted
October 21, 2020
Operation
Air carrier
Aircraft
N922EV
Make and model
Cndair CL6002B19
Aircraft serial
7822
Aircraft time
34,700 hours, 34,802 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 409-559
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT SIDE PRESSURE FLOOR SILL HAS CORROSION AT MULTIPLE LOCATIONS BETWEEN FS 409+128 TO FS 559. C-CHECK RO 10/18/2020. REPAIRED LEFT SIDE PRESSURE FLOOR SILL CORROSION AT MULTIPLE LOCATIONS BETWEEN FS 409+128 TO FS 559, IAW REO. COMPLETED AND ATTACHED TASK CARD & FORM M337. WEIGHT & BALANCE NOT AFFECTED. NOTE REPAIR REQUIRES A DETAILED VISUAL INSPECTION EVERY 8260 FLIGHT CYCLES WITH A REPEAT EVERY 8260 FLIGHT CYCLES FIRST INSPECTION IS DUE AT 43061 FLIGHT CYCLE. REFERENCE ATTACHED CONTINUATION CARD FOR DETAILS OF LOCATIONS OF BLENDING AND WORK PERFORMED.