What was found
EVALUATE LT 9G BULKHEAD AFT SIDE DAMAGE AT INSERT/RIV NUT LOCATIONS, REFERENCE RIL NR 5378. REPAIR IF NEEDED, IAW ENGINEERING INSTRUCTIONS. C-CHECK RO 10/18/2020. COMPLIED WITH MHIRJ EO IN REPAIR OF TOOLING DAMAGE TO LT 9G BULKHEAD AFT WALL. REPAIR DOUBLER MATERIAL 2024-T3 .040 P/O W58363. INSERT 2 EACH P/N CDSP5905-3-44. NEW P-SEAL P/N 1024. P/O W72038. DEPTH GAGE WVACT 204441 CAL DUE 28 FEB 2021. COMPLETED TASK CARD, FORM M-337 ATTACHED. NO WEIGHT REMOVED, TOTAL WEIGHT ADDED 1.715 LBS.