What was found
RIGHT SIDE FLOOR ANGLE BETWEEN APPROXIMATELY FS 813 TO FS 830 HAS CORROSION, MARKED. C-CHECK RO 1/5/2021. REMOVED 3 EA HI-LITES ON RT SIDE FLOOR ANGLE BETWEEN APPROXIMATELY FS 813-FS 830 TO FOM, REF CRJ700 SRM 51-42-21-001-001-A01. INSTALLED 3 EA FASTENERS ON RT SIDE FLOOR ANGLE BETWEEN FS 813 TO FS 830, REF CRJ700 SRM 51-42-21-001-001-A01 AND MHIRJ REO 670-53-41-492 REV DATE 2020-11-07. RESTORED FINISH ON REWORKED AREA, WITHIN LIMITS, REF CRJ700 SRM 51-21-16-001-001-A01 AND MHIRJ REO 670-53-41-492 REV DATE 2020-11-07. COMPLIED WITH 51-900-1002-SKY. COMPLETED FORM M-337. PERFORMED LEAK CHECK, NO LEAKS NOTED. SEE CONTINUATION CARD FOR DETAILS.