What was found
TRANSFER FROM EAML 550059. DENT BETWEEN FS 640 AND 672.2 HAS LARGE DENT APPROXIMATELY 6.4 X 6.3 INCHES WITH HOLE IN CENTER APPROXIMATELY 2.6 X 1.8 INCHES. LT FUSELAGE STRUCTURE DAMAGE BETWEEN FS 640.00 AND FS 672.20, STR 13L AND 16L WAS REPAIRED BY BOMBARDIER MOBILE REPAIR TEAM, IAW REO 601R-53-61-7522 REV DATED 1/3/21. REF ATTACHED BOMBARDIER WORK ORDER. C/W 51-900-1003-SKY AND FORM M-337.