What was found
MINOR CORROSION AROUND NUTPLATE ON FLOORBEAM AT RBL 9 BETWEEN FS 409.00 TO FS 409.00 +16. C-CHECK RO 1/28/2021. REMOVED AND REPLACED FLOORBEAM CAP, IAW REO 601R-53-31-1166 REV- DATED 2021-01-08. COMPLIED WITH TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.