What was found
*L/H INBD FLAP VANE HAS 2EA SMALL CHAFES ON UPPER SURFACE AT CENTER AFT AREA. AREA MARKED. (C-CHECK) RO 2/1/2021 (L/H INBD FLAP VANE 2EA. SMALL CHAFES ON UPPER SURFACE AT CENTER AFT AREA) ORIGINAL MATERIAL THICKNESS BLEND OUT #1 IS .050", REMAINING MATERIAL THICKNESS IS .033", MATERIAL LOSS OF .017". ORIGINAL MATERIAL THICKNESS BLEND OUT #2 IS .050", REMAINING MATERIAL THICKNESS IS .039", MATERIAL LOSS OF .011". BLENDS ARE FOUND TO BE IN LIMITS REF. MHIRJ REO 690-57-52-368 REV. --, DATED 2020-12-16. SEE CONTINUATION CARD FOR WORK DETAILS. COMPLIED WITH SKYWEST FORM M-337 AND SKYWEST TASK CARD 51-900-1002-SKY.