What was found
* AVIONICS BAY AT FS 349.0 FRAME FLANGE HAS AREAS OF CORROSIONI IN BETWEEN STR 25L TO STR26R (C-CHECK) RO 2/1/2021 INSTALLED NEW FRAME IN AVIONICS BAY AT FS 349.0 BETWEEN STR 25L TO STR26R REF CRJ-900-SRM 51-42-21-001-001-A01, CRJ-900-SRM 51-42-06-001-001-A01, DWG 690-31350 REV M, AND DWG SH670-31810 REV AE. COMPLIED WITH 51-900-1002-SKY AND PRESSURE CHECK GOOD . SEE CONTINUATION CARD FOR DETAILS