What was found
* FS 645..00 FRAME BELOW L/H FLOOR SILL AT APPROX STGR 19L CORRODED FWD AND AFT SIDE. (C-CHECK) RO 2/1/2021 PERFORMED FRAME SPLICE REPAIR AT FS645 FROM STGR 16L TO BAGGAGE BAY UPPER LONGERON REF.DWG SH690-33100 REV N,CRJ-900-SRM 51-42-06-001-001-A01,CRJ-900-SRM 51-42-21-001-001-A01,CRJ-900-SRM 51-42-14-001-001-A01, CRJ-900-SRM 51-42-10-001-001-A01, CRJ-900-SRM 53-00-06-201-001-A03. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY AND PRESSURE CHECK GOOD .SEE CONTINUATION CARD FOR DETAILS