As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GALLEY SERVICE DOOR LOWER SILL STRIKER HAS CORROSION WERE AFT AND FWD DOOR STOP FITTING SITS. (C-CHECK) RO 2/1/2021 REMOVED AND REPLACED CORRODED SEAL STRIKER AT GALLEY SERVICE DOOR REF CRJ900 SRM 51-42-06-001-001-A01 AND BOMBARDIER DRW SH670-31412 REV C. LEAK CKECK GOOD AT THIS TIME. ALSO COMPLIED WITH 51-900-1002-SKY.