As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
F.S 333 AT STRG 26L JOINT STRINGER SPLICE CORRODED (C-CHECK) RO 2/1/2021 REMOVED AND REPLACED STINGER SPLICE AT FS333 STGR26L REF CRJ-900 SRM 51-42-06-001-001-A01 AND REF DWG# SH670-32420 REV E SHEET 1 AND 3. SEE ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED. COMPLIED WITH 51-900-1002-SKY. PRESSURE LEAK CHECK GOOD AT THIS TIME.