As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*RIGHT BL9 FLOOR BEAM FROM APPROX. FS 409.00+16 TO APPROX. FS409.00+128 HAS CORROSION. (C-CHECK) RO 2/9/2021 REMOVED AND REPLACED FLOOR BEAM CAP AT RBL9 FLOOR BEAM APPROX. FS409.00+16 - FS409.00+128 REF CRJ200 SRM 51-42-22, SRM 51-42-21, DWG 601R31005 REV B, DWG 601R31030 REV-N AND DWG601R31117 REV E. COMPLIED WITH ALL STEPS OF REO 601R-53-31-1167 REV -- DATED 2021-01-04. COMPLIED WITH TASK CARD 51-900-1003-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.