As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*MULTIPLE SPOTS OF CORROSION ON THE L/H PRESSURE FLOOR SILL FROM FS409.0-128 TO FS559.00 (MARKED) (C-CHECK) RO 2/9/2021 BLENDED CORROSION TO A SMOOTH CONTOUR AND RESTORED FINISH TO REWORKED AREAS. REMAINING MATERIAL IS WITHIN LIMITS. REF REO 601R-53-41-666 REV -C DATED 2012-11-06. COMPLIED WITH TASK CARD 51-900-1003-SKY. LEAK CHECK GOOD.