What was found
PAX DOOR ENTRY WAY, FLOOR SUPPORT MIDDLE CAP ANGLE IS CORRODED. (MARKED) (C-CHECK) RO 2/28/2021 INSTALLED NEW MID CAP ANGLE @PAX DOOR. REF CRJ700 SRM 51-41-00-001-001-A01 COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX DOOR ENTRY WAY, FLOOR SUPPORT MIDDLE CAP ANGLE IS CORRODED. (MARKED) (C-CHECK) RO 2/28/2021 INSTALLED NEW MID CAP ANGLE @PAX DOOR. REF CRJ700 SRM 51-41-00-001-001-A01 COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY