What was found
*STRINGER, STGR26 LEFT, HAS CORROSION AT FASTENERS BETWEEN FS1000 AND FS1031 (MARKED). (C-CHECK RO: 6/20/21) / REMOVED CORROSION ON STGR 26L ATTACH FLANGE AT FS1000-FS1031 REF CRJ700 SRM 51-21-06-001-001-A01 / NO DAMAGE ALLOWED IN STGR ATTACHED FLANGE. REF. CRJ700 SRM 53-61-03-101-003-A01. & BOMBARDIER DRAWING # MM670-35151 REV. R. / COMPLIED WITH REPAIR ON STGR 26L REF REO 670-53-61-1890 REV --, DATED: 2021-05-26 / . COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY. LEAK CHECK GOOD.