As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*FLOOR STRUCTURE: G1 GALLEY MOUNT TOP PLATE AT APPROX FS 317 / RBL 5 HAS EVIDENCE OF CORROSION. (C-CHECK RO 7/27/2021) REPLACED GALLEY 1 MOUNT TOP PLATE AT APPROX FS 317 / RBL 5. REF CRJ200 SRM 51-42-13 AND DWG# 601R38669 REV -N. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY.