What was found
ACCESS REQUIRED AT FS 621 FOR UNDERFLOOR REPAIRS (C-CHECK RO 8/5/2021) PERFORMED ACCESS AT FS621 BY REMOVING AND REINSTALLING LBL 9 FLOOR BEAM FITTING ASSY AT FS62 AND REMOVING AND INSTALLING WEB AT FS 610 BETWEEN LBL 9 AND RBL 9 IAW CRJ 200 SRM 51-41-02, 51-42-06, AND 51-42-21. COMPLETED TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED 337. NO WEIGHT CHANGE. REFERENCE CONTINUATION CARD FOR WORK PERFORMED.