As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
* FOWARD BAGGAGE BAY, CENTER DOOR SURROUND, FWD JOINT PLATE ON RING DOUBLER CORRODED (MARKED) (C-CHECK RO 9/8/2021) REMOVED CORROSION AND EVALUATED REPAIR. REPAIR FOUND TO BE WITHIN LIMITS OF REO 690-53-31-593 REV. -- DATED: 2021-07-14 / SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED. / C/W SKYWEST TASK CARD 51-900-1002-SKY