What was found
* CORROSION DETECTED ON COCKPIT ENTRANCE FLOOR SUPPORT "ANGLE" ON FWD SIDE OF F.S. 280.00 CROSS BEAM (FLAGGED). (C-CHECK RO 9/8/2021) FOUND ENTRANCE FLOOR SUPPORT ANGLE AT FWD SIDE FS280 TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-00-00-101-001-A01. REMOVED AND REPLACED ANGLE FLOOR SUPPORT ON FWD SIDE OF FS280 CROSS BEAM REF. CRJ-900 SRM, 51-42-06-001-001-A01, CRJ-900 SRM, 51-42-21-001-001-A01. DWG CC670-33052 REV --G. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR FURTHER DETAILS.