What was found
* CORROSION DETECTED ON BOTH (L/H AND R/H) F.S. 280.00 BULKHEAD, FLOOR LEVEL POSTS, LBL 9.00 AND RBL 9.00, ON THE ATTACHING "CLIPS" (MARKED). (C-CHECK RO 9/8/2021) FOUND LH AND RH CLIPS AT FS280 FLOOR LEVEL POSTS LBL9 AND RBL9 TO BE OUT OF LIMITS REF. CRJ-900 SRM, 53-00-00-101-001-A01. REMOVED AND REPLACED LH AND RH CLIPS AT FS280 FLOOR LEVEL POSTS LBL9 AND RBL9 REF. CRJ-900 SRM, 51-42-13-001-001-A01, / CRJ-900 SRM, 53-11-10-201-006-A01. CRJ-900 SRM, 51-42-06-001-001-A01 AND DWG CC670-34010 REV J. COMPLIED WITH TASK CARD 51-900-1002-SKY