What was found
RBL 9.00 FLOORBEAM CAP OUTBOARD FLANGE IS HEAVILY CORRODED BETWEEN F.S. 559.00+48 AND F.S. 559.00+80. (C CHECK RO 12/28/2021) UPON FURTHER INVESTIGATION FOUND CORROSION TO BE AT RBL9 OUTBOARD FLANGE BETWEEN FS 559+10 AND FS559+80. CORROSION DAMAGE FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FLOOR BEAM CAP IAW CRJ 200 SRM 51-24-36, 51-40-11, 51-42-21, AND 51-42-22 WITH REO 601R-53-51-605 REV-- DATED 2021-10-16 FOR USE OF ALTERNATE FASTENERS. NO WEIGHT CHANGE NOTED. MAJOR REPAIR TASK CARD 51-900-1003-SKY AND FORM 337 COMPLETED AND ATTACHED. REFER TO CONTINUE CARD AND ATTACHED TASK CARD FOR DETAILS OF WORK PERFORMED.