Service difficulty report · Floorbeam · Cndair CL6002C10

Difficulty date
January 7, 2021
Submitted
March 9, 2021
Operation
Air carrier
Aircraft
N738EV
Make and model
Cndair CL6002C10
Aircraft serial
10146
Aircraft time
25,116 cycles
Part
Floorbeam
Condition
Corroded
Location
Zone 200
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLOOR SILL, F.S. 280 TO SERVICE DOOR CUTOUT APPEARS CORRODED. (C-CHECK) RO 3/8/2021 REMOVED CORROSION AT FLOOR SILL AT FS 280 TO SERVICE DOOR CUTOUT REF CRJ 700 SRM 51-21-06-001-001-A01. 100% MATERIAL LOSS OUT OF LIMITS REF CRJ 700 SRM 53-00-45-201-001-A01. REPLACED FLOOR SILL AT FS 280 TO SERVICE DOOR CUTOUT REF CRJ 700 SRM 51-42-06-001-001-A01 SRM 51-42-21-001-001-A01 SRM 51-42-13-001-001-A01 AND DWG 670-32170 REV: V. AND COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD.