What was found
FLOOR BEAM AT RBL 9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 559.00 TO F.S. 559.00+80 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOORBEAM IAW CRJ200 SRM 51-42-21, 51-42-36 (BOTH REV. 38B, DATED 11/25/20) AND REO 601R-53-51-565 REV. --, DATED 03/09/2021. FORM 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED AND ATTACHED. NO WEIGHT CHANGE. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.