What was found
FOUND CORROSION ON STRINGER 24L AT SEVERAL LOCATIONS (MARKED) BETWEEN FS1000.00 TO FS 1015.00. (C-CHECK RO 4/21/2021) REMOVED CORROSION OG STGR 24L BETWEEN FS1000 TO FS1015 REF CRJ700 SRM 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW STGR 24L STRINGER BETWEEN FS976 TO FS1028 REF CRJ700 SRM 53-00-03-201-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY. PRESSURE CHECK GOOD.