What was found
LEFT PRESSURE FLOOR SILL PANEL IS CORRODED AT 4 LOCATIONS (1) F.S.446.6 LBL43, (2) F.S.483.5 LBL41.5, (3) F.S.493.25 LBL42.5, AND (4) F.S.536 LBL42.5 (C-CHECK RO 4/25/2021) REPAIRED LEFT PRESSURE FLOOR SILL PANEL AT 4 LOCATIONS (1) F.S.446.6 LBL43, (2) F.S.483.5 LBL41.5, (3) F.S.493.25 LBL42.5, AND (4) F.S.536 LBL42.5 IAW MHIRJ REO 601R-53-41-666 REV C DATED 2012-11-06, SKYCARD 51-900-1003-SKY AND ATTACHED FORM M-337 / NO WEIGHT CHANGE