Service difficulty report · Pressure Deck · Cndair CL6002D24

Difficulty date
March 16, 2021
Submitted
May 7, 2021
Operation
Air carrier
Aircraft
N803SK
Make and model
Cndair CL6002D24
Aircraft serial
15062
Aircraft time
37,560 hours, 23,900 cycles
Part
Pressure Deck
Condition
Corroded
Location
Right
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

*MULTIPLE AREAS OF CORROSION ON RH PRESSURE FLOOR SILL PANEL. AREAS MARKED. (C-CHECK RO 5/3/2021) REPAIRED RH PRESSURE FLOOR SILL PANEL PER CRJ900 SRM 51-21-06-001-001-A01 & REO 690-53-41-254 REV --, DATED 2021/04/01. SEE CONTINUATION CARD FOR DETAILS. CHECKS GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY.