What was found
*CORROSION ON LH PRESSURE FLOOR SILL DOUBLER ON FS 797.00, BETWEEN LBL36 €“ LBL45 (C-CHECK RO 5/3/2021) REMOVED CORROSION ON LH PRESSURE FLOOR SILL DOUBLER ON FS797.00 BETWEEN LBL36 AND LBL45 IAW CRJ900 SRM 51-21-06-001-001-A01. EVALUATED AND FOUND TO BE OUT OF LIMITS DUE TO BEING IN A NO DAMAGE ALLOWED AREA. ORIGINAL THICKNESS IS 0.080€? IAW CRJ900 SRM 53-41-44-001-001-A02. REMAINING THICKNESS IS 0.077€?. MATERIAL LOSS IS 0.003€?. RECEIVED AND COMPLIED WITH ALL APPLICABLE STEPS OF REO 690-53-41-255 REV €“ DATED: 2021-03-31.