What was found
* LH SLAT TRACK 3-2 HAS MULIPLE FLAT SPOTS AND PITTING ON THE FWD FACE RAIL, AFT FACE L/E RAILS WITH PITTING AND COROSSION ON THE LOWER END OF THE AFT FACE RAIL (AREAS MARKED) (C-CHECK RO 5/25/2021) .REMOVED FLAT SPOTS / PITTING FROM THE LH SLAT TRACK 3-2, MATERIAL LOSS FOUND TO BE WITHIN LIMITS REF MHIRJ REO 690-57-42-796 REV -- DATED 03/29/21. ALL CHECKS ARE GOOD. SEE CONTINUATION CARD FOR MAINTENANCE PERFORMED. COMPLIED WITH TASK CARD 51-900-1002-SKY