Service difficulty report · Floor Support · Cndair CL6002D24
FAA SDR system
- Difficulty date
- March 17, 2021
- Submitted
- May 27, 2021
- Operation
- Air carrier
- Make and model
- Cndair CL6002D24
- Aircraft serial
- 15159
- Aircraft time
- 32,176 hours, 21,017 cycles
- Part
- Floor Support
- Condition
- Corroded
- Location
- Pressure Deck
- Stage of operation
- IN
- How discovered
- 9
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*CORROSION ON RH PRESSURE FLOOR SILL PANLE BETWEEN FS 785.00 - 813.00, RBL36 - RBL45 (C-CHECK RO 5/25/2021) REMOVED CORROSION FROM RH PRESSURE FLOOR SILL PANEL BETWEEN FS785.00 - 813.00, RBL36 - RBL45, MATERIAL LOSS WITHIN LIMITS AND REPLACED AFFECTED FASTENERS REF MHIRJ REO 690-53-41-257 REV-- DATED 2021-04-05. COMPLIED WITH TASK CARD 51-900-1002-SKY