What was found
* CORROSION DETECTED ON A-BAY DOOR SURROUND STRUCTURE, (FWD/RH) INTERCOSTAL,TO THE RIGHT OF STGR (27). R/H VERTICAL "FACE" AND "FLANGE" , THAT SPANS FROM F.S. 349.00 BACK TO F.S. 364.00 (MARKED). (C-CHECK RO 5/25/2021) REMOVED AND REPLACED INTERCOSTAL TO THE RIGHT ON STGR 27 BETWEEN F.S. 349.00 TO F.S. 364.00, REF CRJ 900 SRM 51-42-06-001-001-A01, CRJ 900 SRM 51-42-21-001-001-A01 AND DWG SH670-32050 REV NC / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY (CL600-2D24) STRUCTURAL MAJOR REPAIR / COMPLIED WITH SKYWEST FORM M-337