What was found
* CORROSION DETECTED ON STGR (22L) BETWEEN F.S. 333.00 AND F.S. 349.00, SEVERAL PLACES AROUND FASTENER BUCKTAILS (MARKED). (C-CHECK RO 5/25/2021) REPAIRED STGR 22L SECTION BETWEEN F.S. 333.00 AND F.S. 349.00, REF CRJ 900 SRM 53-00-03-201-001-A02, CRJ 900 SRM 51-42-06-001-001-A01 AND DWG SH690-31354 REV NC, LEAK CHECK GOOD / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY (CL600-2D24) STRUCTURAL MAJOR REPAIR / COMPLIED WITH SKYWEST FORM M-337