What was found
FLOOR BEAM AT RBL9 HAS MULTIPLE SPOTS OF CORROSION FROM FS559.00 TO FS559.00+80 (C-CHECK RO 6/11/2021) REMOVED AND REPLACED FLOOR BEAM CAP AT FS 409+128- FS 559+8 RBL 9 IAW REO 601R-53-41-2898 REV -- DATED 2021-04-01. REF JOB 97628101 OP 216 CAMP # 22434725 FOR REPLACEMENT OF FLOOR BEAM CAP RBL 9 FS 559+8- FS 559+80. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.