As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*GALLEY SERVICE DOOR, OUTER HANDLE IS CHAFING ON THE HOUSING. (C-CHECK RO: 6/20/21) / REMOVED AND INSTALLED GALLEY SERVICE DOOR HOUSING REF CRJ-700 SRM 51-42-06-001-001-A01 AND DWG NO. CC670-38103 REV -C. OPS TEST GOOD. COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY.